Chapter 1 - Engineering and Administration Procedures
1.01 Introduction
1.02 Definition of Terms
1.03 Scope
1.04 Pre-design Conference
1.05 Plan Preparation Requirements
1.06 Specification Requirements
1.07 Design Computation Requirements
1.08 Estimate Requirements
1.09 Other Permit Applications and Approvals
1.10 Document Submission and Processing
1.11 Approval Period
1.12 Guarantee by Developer
1.13 Plan Review, Inspection & Testing Fees
1.14 Revisions to Approved Plans and Specifications
1.15 Installation & Inspection Procedures
1.16 Record Drawings
1.17 Project Completion and Initial Acceptance
1.18 Waiver for Manual Requirements
1.19 Electronic Drafting File Standards
1.01 INTRODUCTION
A major share of what eventually become publicly owned improvements are designed and constructed by private interest. This manual has been prepared for the purpose of insuring that the design of such improvements will result in construction meeting the requirements of the Town. The intent of this chapter is to explain the processing requirements and procedures as required by the Municipal Code for the various documents required prior to, during, and after construction in order to accomplish these purposes.
The manual is also intended to provide a uniform design criteria for facilities designed for or directly by the Town.
1.02 DEFINITION OF TERMS
The following words and terms, whenever they occur in this manual, shall be interpreted as herein defined.
Abutting (Contiguous, Adjacent). Abutting means have one or more common boundary lines or district lines.
Alley. An alley is a public right-of-way that is less
than thirty- (30) feet wide and affords a secondary means of access
to abutting property.
Frontage on an alley shall not be construed as satisfying the requirements
related to frontage on a public street.
As Built Plans. (See Record Drawings)
Block. A block is a tract of land bounded by public streets, or by a combination of streets and public parks, cemeteries, railroad right-of-way, shorelines of waterways, the corporate limits of the Town of Normal or other lines of demarcation.
Board of Trustees. The Board of Trustees of the Town of Normal.
Building Commissioner is the Building Commissioner of Normal, Illinois, or his duly authorized representative.
Building Setback Line is a line within a lot, or other parcel of land, so designated on the preliminary plan, which denotes the area between such line and the adjacent street right-of-way line where an enclosed building, and other obstructions are prohibited, except those permitted obstructions as regulated by the Normal Zoning Code.
Center Line.
- the centerline of any right-of-way having uniform width;
- the original centerline, where a right-of-way has been widened irregularly;
- the new centerline, whenever a road has been relocated.
City Manager. The individual occupying that position on the staff of the Town of Normal, or his/her duly authorized representative.
Conduit. A buried pipe for the installation of wires or cables or the conveyance of gas, water, storm water or waste water.
Contractor. An individual, company, firm or other party or organization who contracts to physically construct all or a portion of a project for either a developer or the Town.
Cradle. Bedding placed under and around a conduit for proper support.
Cross slope. The degree of inclination measured transversely across pavements rather than longitudinally.
Cul-de-Sac is a minor street with only one outlet.
Design Engineer. The individual, responsible for the design and preparation of plans, specifications, and contract documents. This individual must be a licensed professional engineer in Illinois.
Developer. An individual, company, firm or other party or organization that will be responsible for paying the cost of a project.
Development. Development means both the act of changing and the state of land after its function has been purposefully changed by man including, but not limited to, construction of structures on the land, and alterations to the land, except grading that does not alter the natural flow of storm water.
Director of Public Works. The individual occupying that position on the staff in the Town of Normal or his designated representative.
Drainage way, Improved. A portion of a right-of-way used or intended principally for storm, surface or ground water drainage which does meets or exceeds the design and/or construction standards for public drainage ways.
Drainage way, Unimproved. A portion of a right-of-way used or intended principally for storm, surface or ground water drainage that does not meet or exceed the design and/or construction standards for public drainage ways.
Driveway. A driveway is a private access way for motor vehicles between a public or private street and one or more structures or off-street parking areas.
Lot, Double Frontage is a lot which has a pair of opposite lot lines along two substantially parallel streets.
Easement is a quantity of land set aside over or under which a liberty, privilege, or advantage in land without profit, is dedicated and is distinct from ownership of the land, is granted either to the public, a particular person or a combination of both.
Engineer. A Licensed Professional Engineer licensed by the State of Illinois.
Field Inspector. An individual, company or firm appointed by the Town Engineer to inspect construction to insure compliance with approved plans and specifications.
Final Development Plan is a final plan that is required to be submitted to the Town as specified in the Planned Unit Development regulations, Division 15.9 of the Municipal Code.
Final Plat is a map or plan of a subdivision and any accompanying material as described hereafter.
Final Punch List. A tabulation of deficiencies requiring corrective action prior to Final Acceptance of the Project.
Flood Route. A designated strip or piece of land that will receive the excess surface runoff not accommodated by storm sewer or other drainage facilities.
Frontage. Frontage is the measure of lineal contiguity between a lot and portion thereof and another lot, public street, alley or public way.
Frontage Road is a minor street which is parallel or and either adjacent to or within the right- of-way of a thoroughfare.
Geographic Information System (G.I.S.) A computer system maintained by Bloomington, Normal and McLean County that stores and links non-graphic attributes or geographically referenced data with graphic map features to allow a wide range of information processing and display operations, as well as map production, analysis and modeling.
Illinois Department of Transportation (I.D.O.T.) The division of state government identified by this name.
Live Storage. That volume available in a storm water detention basin for runoff in accordance with the requirements of this Manual.
Lot. A quantity of land capable of being described with such definiteness that its location and boundaries may be established and which is designated by its owner or developer as land to be conveyed, used or developed as a unit or which has been conveyed, used or developed as a unit, including any easements appurtenant thereto. Such lot shall have frontage on a public or private street.
Lot, Double Frontage is a lot which has a pair of opposite lot lines along two substantially parallel streets.
Lot of Record. A lot that is part of a subdivision recorded in the office of the McLean County Recorder of Deeds, or a lot of parcel described by metes and bounds, the description of which has been legally recorded.
Lot, Out. A lot depicted on a final subdivision plat which does not meet the requirements of this Code for lots of record and which may not be used for buildings and parking lots.
Lot, Through. A lot other than a corner lot with frontage on more than one (1) street. Through Lots abutting two (2) streets may be referred to as double frontage lots.
Manual. This document entitled "A Manual of Practice for the Design of Public Improvements in the Town of Normal".
Median. An area between opposite traffic lanes of a street or roadway.
Monument.
- Section Corner Monumentation
- Property Line Monumentation
- G.I.S. Monumentation
Municipal Code. A document adopted by Ordinance by the President and Board of Trustees of the Town of Normal.
"No-Access" Strip is a land area at least one foot wide along a lot line within which no vehicular driveways shall be permitted.
Official Comprehensive Plan (Comprehensive Plan). The Official Comprehensive Plan is the composite of the functional and geographic elements of the Comprehensive Plan of the Town of Normal, or any segment thereof in the form of plans, maps, charts, textual materials and the official map, as adopted by the Town Council.
Official Map. The Official Map is the map adopted by the Town Council as part of the Comprehensive Plan which is designated "Official Map" in that plan.
Official Zoning Map. The Official Zoning Map is the map adopted by the Town Council showing all the zoning district boundaries within the Town of Normal, Illinois.
Parkway (Side Strip) is the unpaved strip of land within a street right-of-way between a curb and right-of-way line.
Pedestrian Way is a right-of-way across or within a block designated for pedestrian use.
Planned Unit Development. A Planned Unit Development is a lot, which is developed as a unit under single ownership or unified control, which includes one (1) or more principal buildings or uses, and is processed under the planned unit development procedure of the Zoning Code.
Planning Commission is the Planning Commission of Normal, Illinois.
Preliminary Development Plan is a tentative map or plan of a proposed development under the Planned Unit Development regulations, Division 15.9 of the Municipal Code.
Preliminary Plan is a tentative map or plan of a proposed subdivision as described in Chapter 16 of the Municipal Code
Project. All of the various parts of proposed construction submitted to the Town Engineer for approval.
Public Improvements. Public improvements includes interior streets, exterior streets, sidewalks, sanitary sewers, storm sewers, water mains, improved drainage ways, bridges, railroad crossings, utility poles and other structures, fixtures or land appurtenances which are or are intended to be dedicated to the Town of Normal and the public generally.
Release Rate. The controlled rate at which storm water is released from a storm water detention basin.
Right-of-Way. A strip of land dedicated to or used by the public for vehicular and/or pedestrian passage storm, surface or ground water drainage or public utility placement.
Roadway. A portion of a right-of-way used or intended principally for vehicular passage, with appurtenant drainage ditches, ways or structures that does to meet or exceed the design standards for the classification it holds.
Setback. The minimum longitudinal distance between the building line or structure and the related front, side or rear property line.
Sidewalk. A portion of a right-of-way used or intended principally for pedestrian passage, which meets or exceeds the design standards for public sidewalks.
Storm Frequency. The frequency of occurrence of a rainfall representing the number of years in which a rain of that magnitude, or larger, will occur. Statistically, it represents the probability of occurrence of a storm event e.g. 100 year frequency storm has 1% probability in any given year, 5 year frequency storm has 20% probability.
Storm Water Detention Basin. A reservoir designed and built for the temporary storage of surface runoff, either on, below or above ground surface accompanied by controlled release of the entire stored water.
Storm Water Retention Basin. A wet bottom reservoir designed and built for the temporary storage of surface runoff, above normal water level of the reservoir, accompanied by controlled release of the part of the stored water above normal water level of the facility.
Street. A street is that portion of a public or private right-of-way used and maintained by a public entity that affords the public the principal means of access to adjacent lots of record or property and meets the design and construction standards for the classification it holds.
Street, Arterial. An arterial street has a high average daily traffic (ADT) and is not intended to be a residential street. A minor arterial street provided connection with major state and interstate roadways and has a high potential for the location of significant community facilities as well as retail, commercial, and industrial facilities.
Street, Boulevard. A street with non-mountable curbing and usually with a grass surface median.
Street, Collector. A collector street functions to conduct traffic between major streets and/or activity centers. It is a principal traffic artery within residential areas and carries moderate volumes of traffic. A collector street has potential for sustaining minor retail or other commercial establishments along its route that will influence the traffic flow.
Street, Cul-de-Sac. A local street with only one outlet that ends with a turn around.
Street, Exterior. A street on the perimeter of a subdivision.
Street, Interior. A street entirely within the confines of a subdivision.
Street, Local. A local street is a short street, cul-de-sac, or court. The primary purpose of a local street is to conduct traffic to and from dwelling units to other streets within the hierarchy of streets.
Street, Minor Arterial. A minor arterial street has a high average daily traffic (ADT) and is not intended to be a residential street. A minor arterial street provides connection with major state and interstate roadways and has a high potential for the location of significant community facilities as well as retail, commercial, and industrial facilities.
Street Standards and Classifications are the current Illinois Department of Transportation classifications and standards as modified by the Town Council pertaining to requirements for streets, as from time to time amended.
Subdivide means (1) the division of land into two or more lots, parcels, or tracts; (2) the dedication of streets, ways, or other areas for use of the public; or (3) any division of land which creates more than one additional lot for transferor ownership and/or building development, or where a new street is involved, or additional utilities, such as sewer or water trunk lines are involved; or (4) or meets the definition of a Planned Unit Development as defined in the Normal Zoning Code; or (5) long term lease.
Subdivision. Subdivision means the configuration of lots of record, out-lots, public rights-of-way and public improvements that result from subdividing land in accordance with the procedures, requirements, and standards of this Code.
Town is the Town of Normal, Illinois.
Town Clerk is the Town Clerk of Normal, Illinois, or her duly authorized representative.
Town Engineer. The individual occupying that position on the staff in the Town of Normal or his designated representative.
Town Planner. The individual occupying that position on the staff of the Town of Normal, Illinois, or his/her duly authorized representative.
Trail. A trail is that portion of right-of-way physically separated from motorized vehicles and intended for non-motorized transportation and recreational uses.
Unified Control. Unified control is the combination of two (2) or more tracts of land either through unified ownership or other arrangement, wherein each owner has agreed to allow use and develop their tracts as a single lot under the provisions of the ordinance applicable to Planned Unit Developments.
Use. The use of property is the purpose or activity for which the land, or building thereon, is designed, arranged, or intended, or for which it is occupied or maintained, and shall include any manner of performance of such activity with respect to the regulations of the Zoning Code.
Walkway. A portion of a right-of-way used or intended principally for pedestrian passage that does not meet or exceed the design standards for public sidewalks.
Watershed. That land area from which all runoff from rainfall would eventually reach the point in question by flowing over the surface of the ground or through existing improvements.
Zoning Administrator. The Zoning Administrator is the Building Commissioner for the Town of Normal, Illinois, or such other person as designated by the Commissioner.
Zoning Map. The Official Zoning Map is the map adopted by the Town Council showing all the zoning district boundaries within the Town of Normal, Illinois.
1.03 SCOPE
The review and approval of plans, specifications, and contract documents for certain types of improvements is also the legal responsibility of various other public agencies in addition to the Town. This Manual is not intended as a substitute for the requirements of such other public agencies. It shall be the Design Engineer's responsibility to see that the proposed plans, specifications, and contract documents meet the legal requirements of all other public agencies and that any and all permits and bonds by such agencies are secured.
1.04 PRE-DESIGN CONFERENCE
It is recommended that prior to the development of a Preliminary Plan and/or detailed Engineering Plans and Specifications the Design Engineer meet with the Town Engineer or his representative to review Town requirements and the proposed project. The Design Engineer, if desired, shall institute the request for this preliminary meeting.
1.05 PLAN PREPARATION REQUIREMENTS
- Subdivision Preliminary Plan and Supporting Documents
- (a.) Required Form of a Preliminary Plan - Plans,
drawings, surveys, maps, schematics, digital submittals,
and comparable material shall be drawn so that clear and
legible transparent or contact prints and photo static (photographic)
copies (reproductions) can be made with a maximum width
of 24 inches (preferably 24" X 36") but with a maximum length
of 36 inches. If the total preliminary plan exceeds more
than one sheet, then a one sheet comprehensive plan of the
entire development and this comprehensive plan sheet will
not exceed 48 inches in width.
(b.) In addition digital computer aided drafting files shall be submitted in accordance with provisions of Section 1.19 of this manual. The official record submittal shall be the signed reproducible copy.
- Required Content of a Preliminary Plan and Supporting
Documents.
- Identification and Description.
- Name of the subdivision, not duplicating the name of any other subdivision, the final plat of which has been recorded in McLean County, Illinois.
- Legal description of all property included in the Preliminary Plan, including a reference to the Section, Township, and Range;
- Name, address, and phone number of the owner or owners of record of all property within the Preliminary Plan;
- Name, address, and phone number of the developer of the proposed subdivision;
- v. Disclosure of the legal relationship, if
any, between the owner and developer, including
any of the following:
- Agent of owner;
- Purchaser under a Contract for Sale with owner, contingent or otherwise;
- Unrecorded owner;
- Contract purchaser.
- Name, address, phone number of the engineering firm preparing the boundary survey;
- Name, address and phone number of the Design Engineer preparing any part of the Preliminary Plan or supporting material;
- Name, address and phone number of attorney(s) representing the owner(s) and/or developer(s);
- The source of all topographical data;
- Total acreage in the Preliminary Plan.
- Survey Maps and Drawings Indicating Existing
Conditions.
A Professional Illinois Land Surveyor or Licensed Professional Engineer shall prepare graphic presentations of the following in each case, with a north point designated as true North and a date of preparation indicated on the survey map, drawing or plan. Unless otherwise noted, the following shall be drawn to an engineering scale not to exceed 100 feet on 1 inch (1000:1) (100'=1"):- Boundary Line Survey Map with accurate distances and angles with a permissible error of closure of 1 in 5000 prepared and certified accurate by an Illinois Professional Land Surveyor:
- Topographic map depicting existing contours at vertical intervals of not more than two feet (0.5m)(2.0'), with reference to U.S.G.S. Datum:
- Location and perimeter of any area designated as a special flood hazard area as defined in Chapter 28 of the Municipal Code. If the property included in the preliminary plan is not in a special flood hazard area the Surveyor or Engineer shall so state on the preliminary plan.
- The existing zoning and zoning district lines within the area encompassed by the Preliminary Plan and the area within 100 feet thereof (30m.):
- Specific identification, location and dimensions,
if applicable, of the following located within 100
feet (30m.) of the area included in the Preliminary
Plan:
- Rights-of-way;
- Streets;
- Roadways;
- Drainage ways; improved;
- Drainage ways; unimproved;
- Walkways and trails;
- Sidewalks;
- Public easements;
- Private easements;
- Railroad rights-of-way;
- Section lines;
- Corporate limit lines;
- Parks, schools, and other public lands;
- Buildings and structures to remain;
- Buildings and structures to be removed.
- Identification, location, size, gradient and invert elevation of sanitary sewers, storm sewers, drainage culverts, catch basins and sanitary and storm sewer manholes located within the area included in the Preliminary Plan, the area within 100 feet (30m) of the perimeter of the area included in the Preliminary Plan or located elsewhere if such constitutes the nearest existing sanitary sewer, storm sewer, drainage culvert, catch basin, sanitary sewer manhole or storm sewer manhole serving the area included in the Preliminary Plan;
- Identification and location of water mains, including all valves and hydrants and any other underground utilities located within the area included in the Preliminary Plan, the area within 100 feet (30m.) of the perimeter of the area included in the Preliminary Plan or located elsewhere if such constitutes the nearest existing water main, valve or hydrant or other underground utility serving the area included in the Preliminary Plan;
- Location of or reference to location of existing monuments or survey markers used in preparation of the boundary line survey map and bench marks;
- Location map drawn to any scale showing an area
bounded by the nearest major or collector street,
but not less than one-half mile (3.0km) (2 miles)
beyond the boundaries of the area included in the
Preliminary Plan.
- Surveys, Maps, Plans and Drawings of Proposed
Conditions
A Registered Professional Engineer shall prepare and certify as accurate to the degree of accuracy specified surveys, maps, plans and drawings with a north point designated as true north and containing a date of preparation depicting the proposed arrangement of the area included in the Preliminary Plan indicating each of the following to an engineering scale not to exceed 100 feet to 1 inch (1000:1);
- Identification, location and dimensions of any
of the following required or proposed:
- Rights of way;
- Interior streets with approximate elevation and proposed gradient;
- Exterior streets with approximate elevation and proposed gradient;
- Exterior roadways with approximate elevation and proposed gradient,
- Street and roadways names;
- Alleys with approximate elevation and proposed gradient,
- Walkways and trails;
- Sidewalks;
- Public easements;
- Private easements;
- Lots,
- Out-lots;
- Minimum front yard setback;
- Other areas proposed for dedication or reservation to the public,
- Railroad crossings and rights-of-way,
- Bridges
- Identification, location and size of any of
the following required or proposed:
- Water mains;
- Valves,
- Hydrants;
- Street lights
- Identification, location, size, gradient, invert
elevation, and typical cross-section of any of the
following required or proposed in the area included
in the Preliminary Plan:
- Drainage ways, improved;
- Drainage ways, unimproved;
- Flood routes.
- Identification, location, size, gradient, surface
elevation, and invert elevation of any of the following
required or proposed in the Preliminary Plan:
- Sanitary Sewers;
- Storm Sewers;
- Sanitary manholes;
- Storm sewer inlets and manholes,
- Sump pump drainage systems.
- Direction of storm water runoff from each lot
and out-lot proposed or required in the Preliminary
Plan.
- Identification, location and dimensions of any
of the following required or proposed:
- The Preliminary Plan shall contain the name and
seal or seals of the professional engineer or engineers
preparing all or any portion of the Preliminary Plan.
All waivers requested of the Town's Codes and ordinances
shall be listed on the Preliminary Plan. Approval of
a Preliminary Plan shall not constitute waiver of any
applicable Town Codes and ordinances unless the President
and Board of Trustees specifically approve the waiver.
- If applicable, accompanying the Preliminary Plan
shall be an application for a Special Flood Hazard Area
development permit as required in section 28.5 of the
Municipal Code. Application form has been provided as
Exhibit L in the Appendix. The Preliminary Plan shall
show the limits of the Special Flood Hazard Area, changes
in grade resulting from excavation and filling, location
and lowest floor elevation of buildings proposed within
the Special Flood Hazard Area.
- Identification and Description.
- Preliminary Plan Submission Procedure.
- Initial Submittal. The owner shall submit to the Town Clerk 22 paper copies of a Preliminary Plan in the form and providing all information required by this manual.
- Final Submittal. Upon approval of a Preliminary
Plan by the Town Council, the owner shall submit 7 paper
and 1 reproducible mylar copies showing any changes
requested by the Town Council. The mylar copy shall
be considered the official copy.
- (a.) Required Form of a Preliminary Plan - Plans,
drawings, surveys, maps, schematics, digital submittals,
and comparable material shall be drawn so that clear and
legible transparent or contact prints and photo static (photographic)
copies (reproductions) can be made with a maximum width
of 24 inches (preferably 24" X 36") but with a maximum length
of 36 inches. If the total preliminary plan exceeds more
than one sheet, then a one sheet comprehensive plan of the
entire development and this comprehensive plan sheet will
not exceed 48 inches in width.
- Public Improvement Engineering Plans and Specifications
- Required Form of Public Improvement Engineering Plans
and Specifications.
- Public improvement engineering plans and specifications, drawings, schematics and comparable material shall be drawn with drawing pencil on transparent abelene or black waterproof drawing ink on mylar from which clear and legible transparent or contact prints and photo static copies can be made, with a maximum width of 24 inches (594 mm), preferably 24" X 36" (594 mm x 841 mm) but with a maximum length of 36 inches (841 mm). This shall be considered the official submittal.
- Supporting material shall be typed on paper not exceeding 8-1/2 inches X 11 inches (A size).
- General drafting requirements:
- Plan sheets shall be drawn to scale. The scale shall be drawn to scale. The scale shall not normally be greater than 1”=50’ (1:600) horizontal and 1” = 10’ (1:100) vertical. The scale shall be clearly labeled on the plan.
- Plan sheets shall include a north arrow. The north arrow should normally be oriented to the left, top or right of the sheet.
- Plan sheets shall include a title block, preferably near the lower right of the sheet. The title block shall include the name and address of the design engineer preparing the plan, the date and the sheet number.
- Stationing shall normally increase from left
to right, south to north and west to east.
- Required Content of Public Improvement Engineering
Plans and Specifications.
- Identification and Description - The public improvement
engineering plans and specifications shall include a
Title Sheet containing the following information:
- The name of the proposed subdivision within which or for which the public improvements are proposed;
- The name, address and phone number of the developer(s);
- The name, address and phone number of the engineering firm preparing any part of the engineering plans and specifications and an indication of the part of the plans that engineer or those engineers prepared;
- Seal or seals of design engineer or engineers preparing all or any portion of the engineering plans and specifications certifying that the materials so prepared conform with all applicable Town codes and ordinances except as specifically noted as a requested waiver.
- Location map drawn to any scale showing area bounded by the limits of the Preliminary Plan for which the engineering plans are all or a portion thereof.
- Two or more benchmark elevations referenced to U.S.G.S. Datum within the boundaries of the project or within 100' (30m.) outside the boundaries of the project.
- An index to all sheets contained within the submitted engineering plans.
- Grading Plan - The public improvement engineering
plans and specifications shall include a Grading
Plan containing (but not limited to) the following
information:
- Existing contours at vertical intervals of not more than two feet (0.5m.), with reference to U.S.G.S. Datum.
- Proposed finish ground surface elevations on all corners.
- Directional arrows of flow of surface waters along rear and side lot lines.
- Elevation of proposed ground surface at all building sites (or pads).
- Location, description, and surface elevation of all drainage structures.
- Directional arrows of flow for flood routing for design storms that exceed the capacity of the proposed storm sewers (minimum of 100 yr. frequency design storm).
- Typical cross sections of flood routing channels showing maximum depth of flow (100 yr. frequency).
- Lot numbers.
- Drainage Way Plan - The public improvement engineering
plans and specifications shall include a Drainage
Way Plan (if applicable) containing (but not limited
to) the following information:
- Existing contours at vertical intervals of not more than two feet (0.5m.), with reference to U.S.G.S. Datum.
- Proposed alignment of centerline of right-of-way and right-of-way width for entire length of proposed improvement and existing alignment for 200' (60m.) upstream and downstream of improvement.
- Proposed and existing profiles for entire length of improvement and existing profile for 200' (60m.) upstream and downstream of improvement.
- Typical cross-section of Drainage way improvement.
- Cross-sections of improvement showing the improvement 100 year flood surface elevation at 50 feet (15m.) intervals.
- Lot numbers.
- Erosion and Sedimentation Control Plan -
the public improvement engineering plans and specifications
shall include a plan for controlling erosion and sedimentation
by one or more of the following methods for the period
when site work commences to the completion of the development:
- Stop erosion on the site by soil stabilization or runoff control measures.
- Allow erosion to take place and then control sediment before it leaves the site.
- A combination of the two previous methods.
- Lot numbers.
- Street, Sidewalk and Trail Plan - The public
improvement engineering plans and specifications shall
include a Street, Sidewalk and Trail Plan containing
(but not limited to) the following information:
- Existing and proposed street alignments showing centerline, face-of-curb, right-of-way, and stationing of roadways.
- Typical cross sections for existing and proposed streets including street pavement, curb and gutter and sidewalks.
- Existing and proposed profiles of pavement referenced to centerline stationing and U.S.G.S. Datum. All proposed vertical curve data shall be shown, including the station and elevation at 15-meter (50 ft) intervals.
- Existing and proposed alignment of sidewalks showing edges of sidewalk.
- Existing and proposed cross sections of roadways on an average horizontal interval of 15 meters (50 ft). (May be omitted for interior streets with curb and gutter.)
- Horizontal curve data for all curvilinear alignments of existing and proposed roadways.
- Lot numbers.
- Storm Sewer Plan - The public improvement
engineering plans shall include a Storm Sewer Plan
containing (but not limited to) the following information:
- Alignment and location of existing and proposed storm sewer conduits and referenced to stationing.
- Location and identification of all existing and proposed drainage structures.
- Size of existing and proposed conduits.
- Profile of proposed conduits showing invert elevations based on U.S.G.S. Datum conduit gradient and crossings of other existing and proposed utilities.
- Locations along alignment of proposed conduit of granular trench backfill placement.
- Lot numbers.
- Sanitary Sewer Plan - the public improvement
engineering plans and specifications shall include a
Sanitary Sewer Plan containing (but not limited
to) the following information:
- Alignment and location of existing and proposed sanitary sewer conduits and referenced to stationing.
- Location and identification of all existing and proposed manholes.
- Location and identification of all proposed sewer services.
- Size of existing and proposed sewer conduits and services.
- Profile of proposed sewer conduits showing invert elevations based on U.S.G.S. Datum, conduit gradient and crossings of other existing and proposed utilities.
- Locations along alignment of proposed sewer conduits and services of granular trench backfill placement.
- Lot numbers.
- Water Main Plan - the public improvement
engineering plans and specifications shall include a
Water Main Plan containing (but not limited to)
the following information:
- Alignment and location of existing and proposed water main conduits and service lines referenced to stationing.
- Location and identification of all existing and proposed valves, fittings and hydrants.
- Location and identification of proposed service lines.
- Size of existing and proposed water main conduits and services.
- Profile of proposed water main conduit showing elevations based on U.S.G.S. Datum and crossings of other existing and proposed utilities. Profiles are not required for interior water mains.
- Locations along alignment of proposed water main conduits and services of granular trench backfill placement.
- Lot numbers.
- Street Light Plan - the public improvement
engineering plans and specifications shall include a
Street Light Plan containing (but not limited
to) the following information:
- Location and identification of existing and proposed street light installation as they relate to the proposed project.
- Lot numbers.
- The street light plan may be included with another required plan.
- Sump Pump Discharge Plan - The public improvement
engineering plans shall include a Sump Pump Discharge
Plan containing (but not limited to) the following
information:
- Alignment and location of existing and proposed sump pump discharge conduits and referenced to stationing.
- Location and identification of all existing and proposed structures including (but not limited to) manholes, junction tees/wyes, and cleanouts.
- Size of existing and proposed conduits.
- Profile of proposed conduits showing invert elevations based on U.S.G.S. datum and crossings of other existing and proposed utilities. (May be omitted for sump pump lines located adjacent to and parallel with a proposed street with curb and gutter if shown on the street typical section.)
- Locations along alignment of proposed conduit of granular trench backfill placement.
- Lot numbers.
- Composite Utility Plan - The public improvement
engineering plans shall include a plan showing all existing
and proposed improvements including but not limited
to:
- Conduits;
- Manholes, tees, hydrants, valves and inlets;
- Size of existing and proposed conduits for water, sanitary and storm sewers and sump pump discharge;
- Lot numbers.
- The Composite Utility Plan may be included with another required plan.
- Specific Details - the public improvement
engineering plans and specifications shall include specific
details containing (but not limited to) the following
information:
- Typical cross sections of streets and right-of- way.
- Intersection details for pavement showing joint locations, elevations, drainage structures and surface water flow.
- Cul-de-sac details showing joint locations, elevations, drainage structure surface water flow and centerline control.
- Standard Details - The public improvement
engineering plans and specifications shall include standard
details containing (but not limited to) the following
information:
Referenced in Chapter
of this Manual1. Pavement, Curb and Gutter Construction 4 2. Sidewalk and Walkway Construction 5 3. Storm/Sump Pump Sewer Construction 6 4. Sanitary Sewer Construction 7 5. Water Main Construction 8
- Identification and Description - The public improvement
engineering plans and specifications shall include a
Title Sheet containing the following information:
- Required Form of Public Improvement Engineering Plans
and Specifications.
- Final Subdivision Plats and Supporting Material
- Required Form of Final Plats.
- Final plats shall be drawn with black waterproof drawing ink on mylar, from which clear and legible transparent or contact prints and photo static copies can be made, with a maximum width of 24 inches (594 mm) preferably 24" X 36" (594 mm x 841 mm), but with a maximum length of 36 inches (841 mm).
- Supporting material shall be typed on paper not
exceeding
8-1/2 inches (210 mm) by 14 inches (356 mm) in size. - Digital submission shall be in accordance with the provisions of Sec. 1.19 of this manual.
- Required Content of Final Plat.
- Identification and Description.
- The name of the subdivision, not duplicating the name of any other subdivision, a final plat of which has been recorded in McLean County, Illinois.
- The legal description of all property included in the final plat, including a reference to the section, township, and range; references to be tied with G.I.S. monuments where available;
- Name and address of the developer of the proposed subdivision;
- Name and address of the Professional Land Surveyor preparing the boundary survey; and
- Total area in the final plat in acres and (hectares.)
- The name of the school district in which the subdivision is located.
- Lot, Out-lot, and Public Improvement Configuration.
Illinois Professional Land Surveyor shall prepare and
certify as accurate angular and lineal dimensions of
all lines, angles and curvatures to an engineering scale
not to exceed 1”=100’ (1:1000) necessary to accurately
depict the location of the following:
- Rights-of-way, including the names of any streets or roadways depicted;
- Public and private easements;
- Proposed lots of record consecutively numbered and keyed on the plat (or on a supplemental sheet) showing the lots platted of the approved preliminary plan (see Exhibit M in the Appendix); lot numbers within a subdivision shall not be repeated even if lots are re-subdivided.
- Out-lots, indicated consecutively and keyed on the plat (or on a supplemental sheet) showing the out-lots platted of the approved preliminary plan;
- Minimum front yard setbacks;
- Other areas dedicated or reserved to the public,
- Railroad rights-of-way;
- Boundaries of the subdivision,
- Field references to:
- The nearest established street lines and monuments which shall be accurately described in the plat by location, and size;
- Township and section lines if the same are within the boundary of the final plat or within 100 feet (30m.) there from, referenced accurately to the lines of the subdivision by distances and angles; this requirement may be waived for re-subdivision of existing final platted lots. This not needed for the survey and are not readily recoverable.
- All monuments placed at all block corners, angle points and at intermediate points installed in such a manner that a Professional Land Surveyor may locate them.
- Reference survey to at least two GIS monuments if available as recorded in order to incorporate plat into GIS based mapping. This requirement may be waived for re-subdivision of existing platted lots of record.
- A signed statement by an Illinois Professional Land Surveyor stating which lots (if any) are located within a Special Flood Hazard Area.
- Certificates - The final plat shall be accompanied by the following certificates duly and appropriately executed in substantially the form presented in the Appendix of the exhibit specified:
- Identification and Description.
- Final Plat Submittal.
The owner shall submit to the Town Clerk two reproducible mylar, sixteen paper and one digital computer aided drafting file copy of the Final Plat in the format and providing all information required by this manual.
- Required Form of Final Plats.
1.06 SPECIFICATION REQUIREMENTS
Technical specifications shall be submitted with the public improvement engineering plans as required in Section 16.3-2 of the Municipal Code and shall be complete in themselves, except that appropriate specific sections of the most recent editions of the "Standard Specifications for Road and Bridge Construction" as published by the Illinois Department of Transportation, and the "Standard Specifications for Water and Sewer Main Construction in Illinois", and the various standard published material specifications prepared by associations such as the "American Society for Testing and Materials" and the "American Water Works Association", may be incorporated by reference.
The specifications shall include (but not limited to) all information not shown on the drawings which is necessary to establish in detail the quality of materials and workmanship required in the project, other parameters for testing the various parts of the project and instructions for testing material and equipment.
The specifications shall include clauses that state:
- All work shall be in conformance with the approved plans and specifications
- All work included in the plans shall be guaranteed by the Contractor to be free from defects in workmanship and materials for a period of twelve months from the date of acceptance by the Town Council.
- The Contractor shall replace or repair any work or material found to be defective in non-conformance within the guarantee period upon written notice from the Town Engineer.
Special provisions specific to construction within the Town are specified in the various chapters of this manual and are to be used as a guide for the preparation of specifications to be submitted to the Town Engineer for review and approval.
1.07 DESIGN COMPUTATION REQUIREMENTS
The Design Engineer shall make design computations for all phases of the project when such computations are required by this manual or in the opinion of the Town Engineer to insure the adequacy and stability of the work, and the work comply with appropriate standards. Said computations shall be neat and legible and in a form required by this manual and that can be readily followed and understood by a competent engineer.
Said computations will include (but not necessarily be limited to) the following:
- Submitted With Subdivision Preliminary Plan: preliminary
design calculations used by the Design Engineer for the following:
- Detention/Retention Basin Design
- Storm Sewer System Design
- Sanitary Sewer Design
- Submitted With Public Improvement Engineering Plans: detailed
design calculations for the following:
- Detention Basin Design
- Storm Sewer System Design
- Sanitary Sewer System Design
- Flood Routing and Waterway Design
- Bridge & Culvert Hydraulic Design
- Structural Design Data for Pavement
- Traffic Projections
- Submitted With Final Subdivision Plats
- Boundary closure calculations.
- All digital submittal information as required in Section 1.19 of this Manual.
- Ties to G.I.S. monuments where available.
Form and content for each set of detailed design computations submitted with Public Improvement Engineering Plans and Final Subdivision Plats are specified in the following chapters of this manual:
| Design Computation | Manual Chapter |
|---|---|
| Boundary Closure Calculations | 3 |
| Bridge & Culvert Hydraulic Design | 10 |
| Coordinate Geometry Calculations for ROW | 3 |
| Detention/Retention Basin Design | 6 |
| Flood Routing & Open Channel Design | 6 |
| Lot Corner Coordinate Data | 3 |
| Sanitary Sewer Design | 7 |
| Sediment & Erosion Control | 13 |
| Storm Sewer System Design | 6 |
1.08 ESTIMATE REQUIREMENTS
The Design Engineer shall prepare a detailed estimate of the cost of the work, categorized to show the various divisions of the work, including engineering costs as a separate item, itemized in such a fashion as to make possible a comparison of the estimated cost with actual cost encountered for similar work in the past.
Estimates of cost will be required as follows:
- At the submittal of public improvement engineering plans and specifications to the Town Engineer for approval.
- Prior to release of funds from escrow accounts posted as security for payment, performance, and workmanship guarantees by the Town Engineer.
- Prior to release of funds from cash reserve accounts posted as security for adjacent substandard roadway improvement guarantee and security by the Town Engineer.
- Submittal of final subdivision plat for approval.
An example form of estimate of cost is provided as Exhibit N in the Appendix of this manual.
1.09 OTHER PERMIT APPLICATIONS AND APPROVALS
Other governmental agencies may review and approve for construction all or certain parts of the work included in a project and may require a permit or application for a permit for such work. They may also require that the Town execute such a permit or application for a permit. When such a permit or permit application is required it shall be prepared, ready for signatures, containing all required supporting documentation, by the Design Engineer with sufficient copies for the Town to retain one.
1.10 PUBLIC IMPROVEMENT ENGINEERING PLANS & SPECIFICATIONS SUBMISSION AND REVIEW PROCEDURE
These documents requiring Town approval shall be submitted by the Design Engineer to the Town Engineer, with a letter of transmittal tabulating the items being submitted. The documents to be approved and the number required by the Town are set out below. The Design Engineer shall add to the documents the quantity he would like returned to him marked approved on their face, or in the case of permit applications, executed by the Town for submittal to other agencies.
The submittal shall be made in two parts. The initial submittal should be made and returned to the Design Engineer prior to the final submittal.
| Documents included in the initial submittal are as follows: | |
| Plans | 2 sets |
| Specifications | 2 sets |
| Design Computations | 2 sets |
After completion of the review of the initial submittal, the Town Engineer will advise the Design Engineer by letter of any items that do not meet the requirements of the Town. The Design Engineer/Developer may then revise the documents and make the final submission.
| Documents in the final submittal shall include the following: | |
| Plans | 6 sets |
| Specifications | 6 sets |
| Estimate | 2 sets |
| Permit Applications | 2 sets |
When the final submittal meets the requirements of this Manual and Town Code, the Town Engineer shall transmit his written approval of the submitted documents to the Design Engineer and City Manager.
1.11 APPROVAL PERIOD
Approval of the public improvement engineering plans and specifications by the Town Engineer shall be applicable for a period for which there is a valid preliminary subdivision plan. If construction is not commenced within said period, the approval will be void. Reactivation of such voided approvals will require a written request for extension which will be considered with due consideration for any new requirements that may be established by the Town in the interim.
1.12 GUARANTEES BY DEVELOPER
Where a developer is constructing proposed work, the developer shall guarantee that all work in the project shall be free from defects in workmanship and materials and in conformance with the approved plans and specifications in accordance with Section 16.2-6 of the Municipal Code.
1.13 PLAN REVIEW, INSPECTION, AND TESTING FEES
In accordance with Section 16.2-4(c) of the Municipal Code and prior to the Town Engineer transmitting his approval of the public improvement engineering plans and specifications and prior to the recording of the final plat, the developer shall pay to the Town a fee of two percent (2%) of the approved estimated costs of such improvements. Said fee shall be applied as credit against the actual costs incurred by the Public Works Department for review of said plans and the inspection and testing of said improvements.
The balance of the actual costs shall be paid to the Town by the Developer at the time such review and inspection has been completed by the Public Works Department and prior to the town accepting the improvements for maintenance.
1.14 REVISIONS TO APPROVED PUBLIC IMPROVEMENT ENGINEERING PLANS & SPECIFICATIONS
Any deviations from approved plans or specifications affecting capacity, the Town Engineer shall approve stability or operation of the improvements in writing before such changes are made. Minor changes not affecting capacity, stability or operation of the improvements will not require formal approval but must be approved by the field inspector representing the Town Engineer.
1.15 INSTALLATION AND INSPECTION PROCEDURES
Prior to construction commencing, the Design Engineer may arrange with the Town Engineer to set and conduct a pre-construction meeting with representatives of contractors, and utility companies present.
1.16 RECORD DRAWINGS
The Design Engineer shall submit to the Town Engineer, within 9 months of the Town's acceptance for maintenance, record drawings of the public improvement engineering plans. Final release of the subdivision bond will not be made until the Town Engineer has received the record drawings. Record drawings submitted shall be one set of clear and legible transparent mylar and one set of photo static prints of the underground improvement plans and one digital computer-aided drafting file in accordance with this Manual, approved depicting the improvements as actually installed or constructed.
The Design Engineer will receive from the Public Works Department all inspection reports required to prepare the record drawings adequately. The inspection reports will be available to the Design Engineer after the improvements have been inspected and tested.
1.17 PROJECT COMPLETION AND FINAL ACCEPTANCE
Prior to the Town Engineer recommending that the Town accept the project for maintenance, the Town Engineer shall make a final inspection of the completed work. The Town Engineer shall then prepare a final punch list, itemizing all items not meeting the requirements of the approved plans and specifications. On the completion of all items listed in the final punch list to the satisfaction of the Town Engineer, the Town Engineer shall recommend in writing to the City Manager that the Town accept the project for maintenance.
1.18 WAIVER FOR MANUAL REQUIREMENTS
Where conditions so warrant, the City Manager, may waive any of the requirements of this manual.
1.19 ELECTRONIC DRAFTING FILE STANDARDS
- Purpose. The purpose of these specifications is to
provide a standard for the transfer media and the format of
the data files for submission to the Clerk of the Town of Normal.
The goal is to save the Town, consultants and developers time
and money by providing a set of CAD (Computer Aided Drafting)
standards that will allow for easier referencing and combining
of files from one or more designs or sets of field data. By
following these standards, files will be uniform allowing for
quicker access and editing of files produced at any time or
by different people. It will also allow the Town to automate
the process of adding data to a GIS (Geographic Information
System).
- Electronic Files Required. The electronic files submitted
will be used for two purposes:
- GIS update – this requires the plat or project to be a homogenous continuous design based in State Plane Coordinates as outlined below in Section D. Notes are not needed.
- Electronic Files – this is the source for each printed
page in a plat or plan. Electronic files shall be provided
when submitting final copies of:
- Preliminary Plans
- Final Plats
- Record drawings of Public Improvement Engineering Plans (including title page, grading plan, drainage way, street, sidewalk and trail (except cross sections), storm sewer, sanitary sewer, water main, street lights, sump pump, structures).
- Electronic files are requested but not required
for record drawings and final plats for subdivisions
approved under the expedited procedure.
- Media. Files may be submitted on 3-1/2 inch diskette,
Iomega 100 MB Zip Disks or CD-Rom. Files on floppy may be zipped
as long as they are self-extracting or the extraction utility
is provided. All files and media are to be an IBM compatible
format.
- CAD Standard. This CAD (Computer Aided Drafting)
standard is based on the IDOT (Illinois Department of Transportation)
drafting standards where feasible. Files submitted shall be
Micro station DGN files or Auto Cad DWG Version 14 or later.
The files shall have the following properties:
- The actual working plat or design project shall use Illinois State Plane East Zone Metric coordinates, USGS Zone 3776, FIPS Zone 1201, Projection will be Transverse Mercator. The USGS Datum will be, horizontal NAD 83 and vertical NGVD 29. The plat or project shall properly edge match to adjoining plats or design.
- Files shall be 3D design files for plans and 2D design for plats. Individual pages such as title page or typical sections may be 2D design files.
- If CAD files are converted from English units to Metric units use 0.3048 ft/m for conversion.”
- If using AutoCAD DWG files the following applies:
- All unused blocks shall be purged from AutoCAD files.
- If using Micro Station DGN files the following apply:
- The Global Origin shall be set to the lower left of the design file.
- Working units shall be metric: 1000 sub units (mm) per master unit (m). One sub unit per positional unit. Master units shall be designated m for meters. Sub units shall be designated mm for millimeters. (Note: Dimensions placed in the design file may be in English units as required for plats or design projects, but the working units shall be metric.)
- Reference files used shall be in the same sub directory as the active design file. The attachment of the reference files done shall be set with “Save Full Path” off.
- Design files shall be compressed, to remove deleted elements, before submittal.
- Element attributes/symbology shall be in accordance with the following table.
| FEATURE TYPE | FEATURE DESCRIPTION | LAYER NAME | COLOR | LINE TYPE |
|---|---|---|---|---|
| ALIGNMENT | STREET CENTER LINE | STREETCL | 1 | CONTINUOUS |
| VEGETATION | ORCHARD | ORCHARD | 84 | DASHED4 |
| TREE | TREE | 84 | CONTINUOUS | |
| WOODLAND | WOODLAND | 84 | DASHED2 | |
| WATER | DETENTION BASIN | DETENTION | 153 | HIDDEN2 |
| LAKE | LAKE | 143 | STREAM | |
| LAKE BODY HIDDEN | LAKE_H | 143 | HIDDEN2 | |
| RIVER | RIVER | 143 | STREAM | |
| RIVER HIDDEN | RIVER_H | 143 | HIDDEN2 | |
| STREAM | STREAM | 143 | STREAM | |
| STREAM HIDDEN | STREAM_H | 143 | HIDDEN2 | |
| SWAMP | SWAMP | 143 | HIDDEN2 | |
| RIGHT OF WAY | ACCESS CONTROL FENCE | AC-FENCE | 43 | CUSTOM |
| EASEMENT | EASEMENT | 43 | CUSTOM | |
| MARKER | MARKER | 43 | CONTINUOUS | |
| STREET LIMITS | STR_LIMIT | 40 | CONTINUOUS | |
| STREET NAME ANNOTATION | STR_ANNO | 3 | CONTINUOUS | |
| NON-HIGHWAY | AREA UNCLASSIFIED | AREA_UC | 32 | DASHED2 |
| ATHLETIC FIELD | ATHLFIELD | 72 | DASHED | |
| BASKETBALL COURT | BBCOURT | 72 | DASHED2 | |
| BUILDING | BUILDING | 141 | CONTINUOUS | |
| BUILDING ANNOTATION | BUILD_ANNO | 3 | CONTINUOUS | |
| CEMETERY | CEMETERY | 41 | DASHED | |
| CONCRETE PLANT | CONCPLNT | 41 | DASHED2 | |
| FENCE | FENCE | 192 | CUSTOM | |
| GOLF COURSE | GOLFCOURSE | 72 | DASHED | |
| JUNKYARD | JUNKYARD | 41 | DASHED | |
| LANDFILL | LANDFILL | 41 | DASHED | |
| MULTI - USE TRAIL | TRAIL | 90 | DASHED | |
| PAVED AIRPORT RUNWAY | RUNWAY_PVD | 152 | CONTINUOUS | |
| POOL | POOL | 170 | CONTINUOUS | |
| QUARRY | QUARRY | 41 | DASHED | |
| RECREATION PARK | PARK | 93 | DASHED2 | |
| SILO | SILO | 142 | CONTINUOUS | |
| STORAGE PILE | PILE | 141 | DASHED2 | |
| STORAGE TANK | STOR_TANK | 141 | CONTINUOUS | |
| TENNIS COURT | TENNIS | 72 | DASHED2 | |
| WATER TOWER/TANK | WATER_TANK | 141 | CONTINUOUS | |
| POLITICAL BOUNDARIES | CORPORATE BOUNDARY | CORP_BNDY | 6 | CUSTOM |
| COUNTY BOUNDARY | COUNTY_BNDY | 5 | CUSTOM | |
| MUNICIPAL BOUNDARY | MUNICIPAL_BNDY | 6 | CUSTOM | |
| TOWNSHIP BOUNDARY | TOWNSHIP_BNDY | 4 | CUSTOM | |
| WARD BOUNDARY | WARD_BNDY | 3 | CUSTOM | |
| TRAFFIC SIGNALS | TRAFFIC SIGNALS | TRAFFIC_SGNL | 4 | CONTINUOUS |
| PRIVATE BOUNDARIES | EXISTING SUBDIVISION LINES | SUB_EXIST | 3 | DASHED4 |
| LOT NUMBER | LOT_NO | 5 | CONTINUOUS | |
| OUTLOTS | OUTLOT | 4 | CONTINUOUS | |
| OWNER NAME | OWNER_NAME | 3 | CONTINUOUS | |
| PROPERTY LINE | PROP_LINE | 4 | CONTINUOUS | |
| PROPERTY LINE DIMENSIONS | PROP_DIMS | 3 | CONTINUOUS | |
| PROPERTY LINE SYMBOL | PROP_SYM | 3 | CONTINUOUS | |
| PROPERTY PINS/PIPES | PROP_PIN | 3 | CONTINUOUS | |
| SAME OWNERSHIP SYMBOL | OWNER_SAME | 3 | CONTINUOUS | |
| SECTION CORNERS | SEC_COR | 5 | CONTINUOUS | |
| SUBDIVISION ANNOTATION | SUB_ANNO | 3 | DASHED2 | |
| SUBDIVISION LINE | SUB_LINE | 6 | CONTINUOUS | |
| SURVEY MARKERS | SURVEY_MK | 3 | CONTINUOUS | |
| EXISTING UTILITIES | COMMUNICATION TOWER | TOWER_COMM | 54 | CONTINUOUS |
| CROSS COUNTRY POLE | POLE_CC | 54 | CONTINUOUS | |
| CROSS COUNTRY TRANSMISSION LINE | PWR_TRNS_LINE | 54 | CONTINUOUS | |
| CROSS COUNTRY TRANSMISSION TOWER | TOWER_TRNS | 54 | CONTINUOUS | |
| FIRE HYDRANT | FIRE_HYD | 170 | CONTINUOUS | |
| MANHOLE COMBINATION | MH_COMB | 100 | CONTINUOUS | |
| MANHOLE SANITARY | SAN_MH | 100 | CONTINUOUS | |
| MANHOLE STORM | STORM_MH | 100 | CONTINUOUS | |
| SEWER COMBINATION | S-COMB | 100 | CONTINUOUS | |
| SEWER SANITARY MAIN | SAN_MAIN | 100 | CONTINUOUS | |
| SEWER STROM MAIN | SS_MAIN | 100 | CONTINUOUS | |
| SUBSTATION | SUBSTATION | 54 | CONTINUOUS | |
| WATER MAIN | W_MAIN | 170 | CONTINUOUS | |
| WATER MAIN VALVE | VALVE_W | 170 | CONTINUOUS | |
| WATER SERVICE VALVE | SER_VALV_W | 170 | CONTINUOUS | |
| NOTES | ALIGNMENT ANNOTATION | ALIGN_ANNO | 3 | CONTINUOUS |
| DRAINAGE STRUCTURES ANNOTATION | DRAIN_STR_ANNO | 3 | CONTINUOUS | |
| TOPOGRAPHY ANNOTATION | TOPO_ANNO | 3 | CONTINUOUS | |
| UTILITY ANNOTATION | UTIL_ANNO | 3 | CONTINUOUS | |
| ROADSIDE FEATURES | DRIVEWAY | DRIVEWAY | 4 | CONTINUOUS |
| PAVED PARKING AREA | PARKING_PVD | 4 | DASHED | |
| RETAINING WALL | WALL_RTN | 4 | CUSTOM | |
| SIDEWALK | SIDEWALK | 4 | CUSTOM | |
| UNPAVED PARKING AREA | PARKING_UNP | 4 | DASHED2 | |
| WALL | WALL | 4 | DASHED | |
| CONTOURS | INDEX CONTOUR LINE | INDX | 43 | CONTINUOUS |
| INDEX CONTOUR DEPRESSION | INDX_D | 43 | DASHED | |
| INDEX CONTOUR DEPRESSION HIDDEN | INDX_DH | 43 | DASHED2 | |
| INDEX CONTOUR HIDDEN | INDX_H | 43 | HIDDEN | |
| INDEX CONTOUR OBSCURE | INDX_O | 43 | HIDDEN2 | |
| INDEX CONTOUR OBSCURE DEPRESSION | INDX_OD | 47 | HIDDEN | |
| INDEX CONTOUR OBSCURE DEPRESSION HIDDEN | INDX_ODH | 47 | HIDDEN2 | |
| INDEX CONTOUR OBSCURE HIDDEN | INDX_OH | 47 | HIDDEN4 | |
| INTERMEDIATE CONTOUR LINE | INT | 53 | CONTINUOUS | |
| INTERMEDIATE CONTOUR DEPRESSION | INT_D | 53 | DASHED | |
| INTERMEDIATE CONTOUR DEPRESSION HIDDEN | INT_DH | 53 | DASHED2 | |
| INTERMEDIATE CONTOUR HIDDEN | INT_H | 53 | HIDDEN | |
| INTERMEDIATE CONTOUR OBSCURE | INT_O | 53 | HIDDEN2 | |
| INTERMEDIATE CONTOUR OBSCURE DEPRESSION | INT_OD | 57 | HIDDEN | |
| INTERMEDIATE CONTOUR OBSCURE DEPRESSION HIDDEN | INT_ODH | 57 | HIDDEN2 | |
| INTERMEDIATE CONTOUR OBSCURE HIDDEN | INT_OH | 57 | HIDDEN4 | |
| EDGE OF PAVEMENT | ALLEY | ALLEY | 2 | CONTINUOUS |
| CONTROLLED ACCESS | ACCESS_CNTL | 62 | CUSTOM | |
| PAVED ROAD BACK OF CURB | ROAD_BOC | 6 | CONTINUOUS | |
| PAVED ROAD BACK OF CURB HIDDEN | ROAD_BOCH | 6 | HIDDEN | |
| PAVED ROAD EDGE OF PAVEMENT | ROAD_EOP | 5 | CONTINUOUS | |
| PAVED ROAD EDGE OF PAVEMENT HIDDEN | ROAD_EOPH | 5 | HIDDEN | |
| ROAD UNCONTROLLED ACCESS | ROAD_UC | 41 | HIDDEN2 | |
| ROAD UNDER BRIDGE | ROAD_H | 6 | HIDDEN | |
| UNPAVED ROAD | ROAD_UNP | 5 | DASHED | |
| UNPAVED ROAD HIDDEN | ROAD_UNPH | 5 | DASHED2 | |
| ROADWAY PLAN | PAVED MEDIAN | MEDIAN_PVD | 6 | CONTINUOUS |
| AS - CONTROL | FAAT PASSPOINTS | FAATPP | 3 | CONTINUOUS |
| HORIZONTAL AND VERTICAL CONTROL POINTS | HVPT | 3 | CONTINUOUS | |
| HORIZONTAL CONTROL POINTS | HPT | 3 | CONTINUOUS | |
| VERTICAL CONTROL POINTS | VPT | 3 | CONTINUOUS | |
| AS - SPOT ELEVATIONS | DIGITAL TERRAIN MODEL BREAKLINE | DTM_BLINE | 1 | CONTINUOUS |
| DIGITAL TERRAIN MODEL POINT | DTM_POINT | 1 | CONTINUOUS | |
| SPOT ELEVATION | SPOT | 3 | CONTINUOUS | |
| WATER ELEVATION | SPOT_WATER | 3 | CONTINUOUS | |
| AS - GRID | 200-METER TICKS (ILL. ST. PLANE EAST) | TICKS_M | 4 | CONTINUOUS |
| ST. PLANE TICKS (ALONG SECTION LINES) | TICKS_F | 3 | CONTINUOUS | |
| AS - MAP LIMITS | MAP MASK AND TITLE | MASK | 7 | CONTINUOUS |
| SECTION LINES | SEC_LINE | 5 | CUSTOM | |
| EXISTING DRAINAGE | CONCRETE DAM | DAM_CONC | 13 | CONTINUOUS |
| DITCH | DITCH | 12 | HIDDEN2 | |
| FLOODWALL / HEADWALL | FLOODWALL | 131 | CONTINUOUS | |
| FLOODWAY | FLOODWAY | 145 | CONTINUOUS | |
| PIER | PIER | 131 | CONTINUOUS | |
| RAILROAD | ABANDONED RAILROAD | RR_ABND | 41 | CONTINUOUS |
| RAILROAD ANNOTATION | RR_ANNO | 3 | CONTINUOUS | |
| RAILROAD CENTERLINE | RR | 4 | CONTINUOUS | |
| RAILROAD CENTERLINE HIDDEN | RR_H | 4 | HIDDEN2 | |
| STRUCTURES | BRIDGE DECK BOUNDARY | BRIDGE | 5 | CONTINUOUS |
| MAJOR CULVERT | CULVERT | 140 | CONTINUOUS | |
| COORDINATE DATA | ILLINOIS STATE PLANE COORDINATE DATA ENGLISH | SPC_E | 7 | CONTINUOUS |
| ILLINOIS STATE PLANE COORDINATE DATA METRIC | SPC_M | 7 | CONTINUOUS |